Back to the list of connectors
EMC Celerra/VNX Unified System (SSH)
Description
This connector provides hardware monitoring by connecting to the Control Server of EMC Celerra and EMC VNX Unified Systems.
Connector ID: EMCCelerra
This connector supersedes:
Target
Typical platforms: EMC Celerra, EMC VNX Unified
Operating system: Storage System
Prerequisites
Leverages: EMC naviseccli and nas_inventory utilities
Technology and protocols: System Commands
Examples
CLI
hws HOSTNAME -t storage -f EMCCelerra --ssh -u USER
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: storage
selectedConnectors: [ EMCCelerra ] # Optional, to load only this connector
ssh:
username: <USERNAME> # Change with actual credentials
password: <PASSWORD> # Encrypted using hws-encrypt
Connector Activation Criteria
The EMC Celerra/VNX Unified System (SSH) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The command below succeeds on the monitored host
- Command:
/nas/bin/nas_inventory - Output contains:
Error 2100(regex)
- Command:
Metrics
| Type | Collected Metrics | Specific Attributes (Labels) |
|---|---|---|
| Enclosure |
|
|
| Processor |
|
|
| Logical Disk, RAID |
|
|
| Memory Module |
|
|
| Network Card, FC Port |
|
|
| Other Device |
|
|
| Physical Disk |
|
|
| Power Supply |
|
|
Search Results for {{siteSearch | truncate:'50'}}
{{resultArray.length}}
No results.