Back to the list of connectors

DataDirect Networks (DDN) Disk Array (SNMP)

Description

This connector discovers the enclosure and the disks of DDN (DataDirect Networks) disk arrays as well as the various environment sensors (temperatures, fans, power supplies). It relies on the SNMP protocol.

Connector ID: DDN

Target

Typical platform: DataDirect Networks (DDN)

Operating system: Storage System

Prerequisites

Leverages: DDN SNMP Agent

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Examples

CLI

hws HOSTNAME -t storage -f DDN --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: storage
  selectedConnectors: [ DDN ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The DataDirect Networks (DDN) Disk Array (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.6894.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="present"}
  • model
  • type
  • vendor
Fan
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
    Physical Disk
    • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
    • hw.status{hw.type="physical_disk",state="present"}
    • vendor
    Power Supply
    • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
    • hw.status{hw.type="power_supply",state="present"}
      Temperature Sensor
      • hw.status{hw.type="temperature",state="ok|degraded|failed"}
      • hw.status{hw.type="temperature",state="present"}
      • sensor_location
      No results.