Back to the list of connectors
IBM AIX - Environment (uesensor)
Description
This connector provides hardware environment information on IBM AIX systems (temperature sensors, voltage sensors, fans, power supplies).
Connector file name: MS_HW_IBMAIXUeSensor.hdf
This connector is superseded by:
Target
Typical platform: IBM POWER
Operating system: IBM AIX
Prerequisites
Leverages: IBM AIX system commands (uesensor)
Technology and protocols: System Commands
Connector Activation Criteria
The IBM AIX - Environment (uesensor) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- Operating System is IBM AIX
- The command below succeeds on the monitored host
- Command:
/bin/ls /usr/lpp/diagnostics/bin/uesensor - Output contains:
^/usr/lpp/diagnostics/bin/uesensor$(regex)
- Command:
- The command below succeeds on the monitored host
- Command:
/usr/lpp/diagnostics/bin/uesensor -a - Output contains:
^3 \|^9001 \|^9002 \|^9004(regex)
- Command:
Monitors
| Object Type | Collected Parameters | Discovered Properties |
|---|---|---|
Fan (MS_HW_FAN) |
|
|
Power Supply (MS_HW_POWERSUPPLY) |
|
|
Temperature Sensor (MS_HW_TEMPERATURE) |
|
|
Voltage Sensor (MS_HW_VOLTAGE) |
|
|