Back to the list of connectors
Hitachi HDS AMS/HUS (SNM2 CLI on Windows)
Description
This connector discovers the status of Hitachi AMS/HUS's processors, CSW, cache, SM, power supplies, batteries, fans, physical disks and environment sensors.
Connector file name: MS_HW_HitachiSNM2CLINT.hdf
Target
Typical platforms: Hitachi AMS, Hitachi HUS
Operating system: Storage System
Prerequisites
Leverages: Hitachi SNM2 CLI
Technology and protocols: System Commands
Connector Activation Criteria
The Hitachi HDS AMS/HUS (SNM2 CLI on Windows) connector must be selected manually, and its status will be reported as OK if all the below criteria are met:
- The command below succeeds on the agent host
- Command:
echo %OS% - Output contains:
Windows_NT(regex)
- Command:
- The command below succeeds on the agent host
- Command:
IF DEFINED STONAVM_HOME ( echo STONAVM_HOME Defined ) - Output contains:
STONAVM_HOME Defined(regex)
- Command:
- The command below succeeds on the agent host
- Command:
set STONAVM_RSP_PASS=on&& echo %{PASSWORD}> "%STONAVM_HOME%\MS_HW_pwdfile" && "%STONAVM_HOME%\auaccountenv" -set -uid %{USERNAME} -passwdfile "%STONAVM_HOME%\MS_HW_pwdfile" - Output contains:
The account information has been set successfully(regex)
- Command:
Monitors
| Object Type | Collected Parameters | Discovered Properties |
|---|---|---|
Enclosure (MS_HW_ENCLOSURE) |
|
|
Battery (MS_HW_BATTERY) |
|
|
Fan (MS_HW_FAN) |
|
|
Logical Disk, RAID (MS_HW_LOGICALDISK) |
|
|
Memory Module (MS_HW_MEMORY) |
|
|
Network Card, FC Port (MS_HW_NETWORK) |
|
|
Other Device (MS_HW_OTHERDEVICE) |
|
|
Physical Disk (MS_HW_PHYSICALDISK) |
|
|
Power Supply (MS_HW_POWERSUPPLY) |
|
|