Back to the list of connectors
IBM Director Agent 5.10.x - Linux
Description
This connector enables hardware monitoring through the IBM Director Agent version 5.x which supports some (not all) xSeries servers.
Connector file name: MS_HW_Director5Linux.hdf
This connector supersedes:
Target
Typical platform: IBM xSeries
Operating system: Linux
Prerequisites
Leverages: IBM Director Agent 5.10.x
Technology and protocols: WBEM
Connector Activation Criteria
The IBM Director Agent 5.10.x - Linux connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- Operating System is Linux
- At least one process for which the command line matches with the regular expression below is running:
cimserver - The WBEM query below to the managed host succeeds:
- Namespace:
root - WQL Query:
SELECT Name FROM __NAMESPACE - Result contains:
^ibmsd;*$(regex)
- Namespace:
- The WBEM query below to the managed host succeeds:
- Namespace:
root/ibmsd - WQL Query:
SELECT Version FROM IBMPSG_DirectorAgent - Result contains:
^5\.[01].*(regex)
- Namespace:
- The WBEM query below to the managed host succeeds:
- Namespace:
root/ibmsd - WQL Query:
SELECT Name FROM IBMPSG_ComputerSystemDetails
- Namespace:
Monitors
| Object Type | Collected Parameters | Discovered Properties |
|---|---|---|
Enclosure (MS_HW_ENCLOSURE) |
|
|
Disk Controller (MS_HW_DISKCONTROLLER) |
|
|
Processor (MS_HW_CPU) |
|
|
Fan (MS_HW_FAN) |
|
|
Logical Disk, RAID (MS_HW_LOGICALDISK) |
|
|
Memory Module (MS_HW_MEMORY) |
|
|
Physical Disk (MS_HW_PHYSICALDISK) |
|
|
Power Supply (MS_HW_POWERSUPPLY) |
|
|
Temperature Sensor (MS_HW_TEMPERATURE) |
|
|
Voltage Sensor (MS_HW_VOLTAGE) |
|
|